@skip_if_github_validation
@scope_power_management
@scope_cobbler
@sle_minion
Feature: 0032 - Redfish Power management
File name: srv_power_management_redfish.feature
Relative path: secondary/srv_power_management_redfish.feature
@skip_if_github_validation
@scope_power_management
@scope_cobbler
@sle_minion
Scenario: Save power management values for Redfish
Given
I am on the Systems overview page of this "sle_minion"
00:00:01.562
When
I follow "Provisioning" in the content area
00:00:00.073
And
I follow "Power Management" in the content area
00:00:00.068
And
I enter the controller hostname as the redfish server address
00:00:00.109
And
I enter "ipmiusr" as "powerUsername"
00:00:00.057
And
I enter "test" as "powerPassword"
00:00:00.052
And
I select "Redfish" from "powerType"
00:00:00.083
And
I click on "Save"
00:00:00.068
Then
I should see a "Power settings saved" text
00:00:00.177
And
the cobbler report should contain ":8443" for "sle_minion"
00:00:03.294
And
the cobbler report should contain "Power Management Username : ipmiusr" for "sle_minion"
00:00:03.186
And
the cobbler report should contain "Power Management Password : test" for "sle_minion"
00:00:04.741
And
the cobbler report should contain "Power Management Type : redfish" for "sle_minion"
00:00:03.158
@skip_if_github_validation
@scope_power_management
@scope_cobbler
@sle_minion
Scenario: Test Redfish functions
When
I follow "Provisioning" in the content area
00:00:00.067
And
I follow "Power Management" in the content area
00:00:00.063
And
I click on "Power On"
00:00:00.822
And
I click on "Get status"
00:00:00.847
Then
I should see the power is "On"
00:00:00.044
When
I click on "Power Off"
00:00:00.863
Then
I should see a "system has been powered off" text
00:00:00.167
And
I should see the power is "Unknown"
00:00:00.042
When
I click on "Get status"
00:00:00.769
Then
I should see the power is "Off"
00:00:00.039
When
I click on "Power On"
00:00:00.858
Then
I should see a "system has been powered on" text
00:00:00.173
When
I click on "Get status"
00:00:00.771
Then
I should see the power is "On"
00:00:00.041
When
I click on "Reboot"
00:00:06.406
Then
I should see a "system has been rebooted" text
00:00:00.174
When
I click on "Get status"
00:00:00.912
Then
I should see the power is "On"
00:00:00.041
@skip_if_github_validation
@scope_power_management
@scope_cobbler
@sle_minion
Scenario: Check power management SSM configuration for Redfish
When
I follow the left menu "Systems > System List > All"
00:00:00.161
And
I click on the clear SSM button
00:00:00.057
And
I check the "sle_minion" client
00:00:00.414
And
I follow the left menu "Systems > System Set Manager > Overview"
00:00:00.478
And
I follow "Configure power management" in the content area
00:00:00.070
Then
I should see "sle_minion" as link
00:00:00.015
And
I should see a "Change Power Management Configuration" text
00:00:00.174
And
I should see a "Type" text
00:00:00.170
And
I should see a "Network address" text
00:00:00.176
And
I should see a "Username" text
00:00:00.169
And
I should see a "Password" text
00:00:00.169
And
I should see a "System identifier" text
00:00:00.172
And
I should see a "Update" button
00:00:00.019
When
I enter "testing" as "powerUsername"
00:00:00.064
And
I enter "qwertz" as "powerPassword"
00:00:00.055
And
I click on "Update"
00:00:00.419
Then
I should see a "Configuration successfully saved for 1 system(s)" text
00:00:00.189
And
the cobbler report should contain "Power Management Username : testing" for "sle_minion"
00:00:03.551
And
the cobbler report should contain "Power Management Password : qwertz" for "sle_minion"
00:00:05.167
And
the cobbler report should contain ":8443" for "sle_minion"
00:00:03.216
And
the cobbler report should contain "Power Management Type : redfish" for "sle_minion"
00:00:03.188
@skip_if_github_validation
@scope_power_management
@scope_cobbler
@sle_minion
Scenario: Check power management SSM operation for Redfish
And
I follow the left menu "Systems > System Set Manager > Overview"
00:00:00.081
When
I follow "power management operations" in the content area
00:00:00.072
Then
I should see "sle_minion" as link
00:00:00.012
And
I should see a "Power On" button
00:00:00.018
And
I should see a "Power Off" button
00:00:00.019
And
I should see a "Reboot" button
00:00:00.018
@skip_if_github_validation
@scope_power_management
@scope_cobbler
@sle_minion
Scenario: Cleanup: reset Redfish values
Given
I want to operate on this "sle_minion"
00:00:00.971
When
I set power management value "" for "powerAddress"
00:00:00.971
And
I set power management value "" for "powerUsername"
00:00:01.049
And
I set power management value "" for "powerPassword"
00:00:01.086
And
I set power management value "ipmilan" for "powerType"
00:00:01.012
Then
the cobbler report should contain "Power Management Address :" for "sle_minion"
00:00:04.981
And
the cobbler report should contain "Power Management Username :" for "sle_minion"
00:00:03.180
And
the cobbler report should contain "Power Management Password :" for "sle_minion"
00:00:03.164
And
the cobbler report should contain "Power Management Type : ipmilan" for "sle_minion"
00:00:03.269